Elsist UPS Flexible 6000VA/5400W, On-line double conversion, DSP, rack/tower, LCD

2.871,76 €
DOSTUPNOST NA UPIT
Pošaljite upit na webshop@lost.hr ili nas nazovite na + 385 (0)1 8000 710;
  • Šifra proizvoda
  • 48134
  • Kataloški broj
  • FLEXIBLE 6000
  • Jamstvo
  • 24 mjeseca
  • Raspoloživost
  • na upit
- FLEXIBLE series can be installed in rack or tower version, it is a true On-line UPS with double conversion tecnology and DSP control (Digital Signal Processor)
- It is possible to increase the back up time with additional battery packs
- USB and RS232 are standard comunications ports, and also RJ45 filter port is available by default
- EPO contact is included and it is possible to use SNMP or RELAY CARD (optional) with Intelligent slot port on the rear panel
- FLEXIBLE is configured with terminal block (input and output), perfectly suitable for every kind of industrial applications
- FLEXIBLE is the best in class UPS with high quality - Its your best choice to protect critical load

Specifications
- Phase: Single phase with ground
- Power: 6000VA / 5400W

INPUT
- Nominal Voltage: 208/220/230/240VAC
- Operating voltage range:
* Low line transfer:
187Vac +/-5% @ 100% - 80% load
160Vac +/-5% @ 80% - 70% load
140Vac +/-5% @ 70% - 60% load
120Vac +/-5% @ 60% - 50% load
110Vac +/-5% @ 50% - 0% load
* Ambient Temp. <35C
* High line transfer: 300Vac +/-5%
* High line comeback: 290Vac +/-5%
- Operating frequency range: 40 - 70 Hz
- Power factor: >0.99@100% load (Nominal Input Voltage)
- Generator input: Supported

OUTPUT
- Output voltage: 208/220/230/240Vac
- Power factor: 0.9
- Voltage regulation: +/- 1%
- Frequency:
* Line Mode (synchronized range): 40 - 70 Hz
* Battery Mode: (50/60 +/-0.1) Hz
- Crest factor: 03:01:00
- Harmonic distortion (THDv):
* <2% THDwith linear load
* <5% THD with non linear load
- Waveform: Pure Sinewave
- Transfer time:
* AC mode <-> Batt. Mode: Zero
* Inverter <-> bypass: 4ms (Typical)
- Efficiency:
* >94% (AC mode)
* >89% (DC mode)

BATTERY
- Battery Type: depends on the capacity of external batteries
- Numbers: 16/20
- 16/20: Long run unit depends on the capacity of external batteries
- Typical recharge time(standard modle): 4 hours recover to 90% capacity (Typical)
- Charging voltage: 137/219.2 VDC +/-1%
- Charge current: 12A max,can be setting by LCD

SYSTEM FEATURES
- Line Mode / Battery Mode:
* Ambient Temp. <35C:
** 105% - 110%: UPS shuts down after 60 minutes at battery mode or transfer to bypass when the utility is normal
** 110% - 130%: UPS shuts down after 5 minutes at battery mode or transfer to bypass when the utility is normal
** >130%: UPS shuts down after 3 seconds at battery mode or transfer to bypass when the utility is normal
* 35C ** 105% - 110%: UPS shuts down after 1 minutes at battery mode or transfer to bypass when the utility is normal
** >110%: UPS shuts down after 3 seconds at battery mode or transfer to bypass when the utility is normal
- Short Circuit: Hold Whole System
- Overheating: Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately
- Low battery voltage: Alarm and Switch off
- EPO (optional): Shut down UPS immediately
- Audible & Visual alarms: Line Failure, Battery Low, Overload, System Fault
- Comunication interface: USB (or RS232), SNMP Card (optional), Relay Card (optional)

ENVIRONMENTAL
- Operating temperature: 0C to 40C
- Storage temperature: -25C to 55C
- Humidity range: 20-90% RH @ 0- 40C (non-condensing)
- Altitude: <1500m
- Noise level Less than: 50dBA at 1 Meter

PHYSICAL
- Dimension (W×H×D): 440×86×490 mm

STANDARDS
- Safety: IEC/EN62040-1, IEC/EN60950-1
- EMC: IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8
 
  • 1 fazni/3 fazni
  • 1 Fazni
  • Rack/Tower/Compact
  • Rack/Tower
  • Vrsta
  • On-line double conversion
  • Robna marka
  • (595-57)
  • grupa
  • BESPREKIDNA NAPAJANJA (UPS)
  • grupa
  • PERIFERIJA
  • brand
  • ELSIST